An algorithm to measure in Anechoic Chamber (AC) the antenna Phase Center (PhC) position is presented. It is based on the assumption that the PhC belongs to the geometrical symmetry axis of the antenna under test. In particular, the algorithm is able to account for the possible presence of an unknown misalignment between such axis and the rotation axis of the turntable of the AC, thus extending the two point-approach available in the literature. The method has been validated through measurements on an X-band microstrip radar antenna.

Measurement of the Antenna Phase Center Position in Anechoic Chamber

Gifuni A.;Perna S.
2018-01-01

Abstract

An algorithm to measure in Anechoic Chamber (AC) the antenna Phase Center (PhC) position is presented. It is based on the assumption that the PhC belongs to the geometrical symmetry axis of the antenna under test. In particular, the algorithm is able to account for the possible presence of an unknown misalignment between such axis and the rotation axis of the turntable of the AC, thus extending the two point-approach available in the literature. The method has been validated through measurements on an X-band microstrip radar antenna.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11367/76425
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact