This paper describes the design and the experimental validation of a multivariable digital controller for a Tokamak, the Tokamak à configuration variable (TCV). The design of the controller is based on a linearized model of the plasma confined in the Tokamak. The plant is multiple-input-multiple-output (MIMO) and the various outputs are strongly coupled. Moreover the plant is open-loop unstable. The scope of the controller is to stabilize the plasma and to guarantee some closed-loop performance in terms of decoupling among the plant outputs. The proposed controller is composed of two nested loops: one is devoted to the vertical stabilization, the other, designed using the H∞technique, guarantees the control of the plasma current and of the plasma shape. After massive simulations, this controller has been successfully tested on the plant. The experimental results show a significant improvement of the performance with respect to those obtained with a proportional integral derivative (PID) MIMO controller, that was used before on the plant.

Design and experimental testing of a robust multivariable controller on a Tokamak

Ariola, Marco;
2002-01-01

Abstract

This paper describes the design and the experimental validation of a multivariable digital controller for a Tokamak, the Tokamak à configuration variable (TCV). The design of the controller is based on a linearized model of the plasma confined in the Tokamak. The plant is multiple-input-multiple-output (MIMO) and the various outputs are strongly coupled. Moreover the plant is open-loop unstable. The scope of the controller is to stabilize the plasma and to guarantee some closed-loop performance in terms of decoupling among the plant outputs. The proposed controller is composed of two nested loops: one is devoted to the vertical stabilization, the other, designed using the H∞technique, guarantees the control of the plasma current and of the plasma shape. After massive simulations, this controller has been successfully tested on the plant. The experimental results show a significant improvement of the performance with respect to those obtained with a proportional integral derivative (PID) MIMO controller, that was used before on the plant.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11367/68052
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 27
social impact