We propose a comparative dosimetric study of whole-breast hypofractionated radiation therapy using helical tomotherapy (HT) in supine position and 3-D conformal radiotherapy (3D-CRT) in prone position. Twelve patients undergoing breast-conserving therapy were retrospectively selected from October to December 2012. Specific dose-volume parameters were selected for the study. The target coverage was adequate in all patients for both techniques. Significant differences in lung dose distribution were observed: maximum dose (mean value over the 12 plans) was 23.41 Gy in HT plans and 6.65 Gy in 3D-CRT; V20 (i.e. the lung volume receiving 20 Gy) was 0.31% in HT plans and 0.0% in 3D-CRT plans. The mean dose to the heart was 5.57 Gy and 0.93 Gy, respectively. The differences between the two techniques were significant (p<0.05) only for some parameters. We noted better results in the prone position, but with HT, dose constraints were mentioned for the whole set of considered organs.

Hypofractionated breast cancer radiotherapy. Helical tomotherapy in supine position or classic 3D-conformal radiotherapy in prone position: which is better?

CUTILLO, Luisa;
2014-01-01

Abstract

We propose a comparative dosimetric study of whole-breast hypofractionated radiation therapy using helical tomotherapy (HT) in supine position and 3-D conformal radiotherapy (3D-CRT) in prone position. Twelve patients undergoing breast-conserving therapy were retrospectively selected from October to December 2012. Specific dose-volume parameters were selected for the study. The target coverage was adequate in all patients for both techniques. Significant differences in lung dose distribution were observed: maximum dose (mean value over the 12 plans) was 23.41 Gy in HT plans and 6.65 Gy in 3D-CRT; V20 (i.e. the lung volume receiving 20 Gy) was 0.31% in HT plans and 0.0% in 3D-CRT plans. The mean dose to the heart was 5.57 Gy and 0.93 Gy, respectively. The differences between the two techniques were significant (p<0.05) only for some parameters. We noted better results in the prone position, but with HT, dose constraints were mentioned for the whole set of considered organs.
File in questo prodotto:
File Dimensione Formato  
Mammella.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: Dominio pubblico
Dimensione 85.6 kB
Formato Adobe PDF
85.6 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11367/31491
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 7
social impact